Globus Physiolaser 12.0 PRO

Item N. G5803

Ean 8032625829140

  • High-performance device for medical laser therapy in physiotherapy and rehabilitation
  • 12-watt laser treatment (808 nm) for high-intensity laser therapy
  • Extended program library for standardized clinical applications
  • Optionally expandable with additional wavelengths (depending on configuration)
  • Designed for high patient throughput in professional practice and clinical environments
€6,490.00

Availability: 5 - 7 working days

* incl. VAT excl. shipping

truck

Convenient shipping

International convenient shipping throughout Europe

information-circle

Secure shopping

Fast shipping, customer protection, secure payment

Description

Globus PhysioLaser 12.0 PRO – High-Performance Device

The GLOBUS PhysioLaser 12.0 PRO is a medical laser therapy device designed for professional use in physiotherapy, rehabilitation, orthopedics, and sports medicine. As a high-performance class system, it operates with a maximum output of 12 watts laser treatment (808 nm). The device is intended for regular use in clinics and physiotherapy practices and is particularly suitable for treating larger or more complex treatment areas. Its design allows flexible use in daily clinical workflows and supports structured, repeatable applications.

Key Features

  • Medical device for professional laser therapy applications

  • High-performance 12-watt laser treatment (808 nm) for intensive applications

  • Suitable for acute and chronic musculoskeletal conditions

  • Wide program library for standard physiotherapy indications

  • Optionally expandable to additional wavelengths (980 nm / 1064 nm depending on configuration)

  • Use in physiotherapy, orthopedics, and rehabilitation medicine

  • Treatment of larger body areas via high-performance optics

  • Battery and mains operation for flexible clinical use

  • Suitable for high patient volumes and regular treatments

  • Structured, program-guided operation

Laser Therapy Function

Laser therapy is based on the targeted application of light energy into biological tissue. The PhysioLaser 12.0 Pro operates at a standard wavelength of 808 nm, widely used in physical therapy for musculoskeletal treatment. The 12-watt output enables high energy delivery into tissue and is used for localized treatment of muscles, tendons, joints, as well as inflammatory and degenerative conditions. The application is non-invasive and delivered via a laser handpiece.

High-Intensity Laser Therapy in Clinical Practice

The PhysioLaser 12.0 Pro is designed for high-intensity laser therapy and enables efficient treatment of larger surface areas or deeper tissue structures due to its power reserve. The combination of high output and program-guided operation supports structured treatment workflows in both practice and clinical environments.

Indications

The PhysioLaser 12.0 Pro is used in physiotherapy and rehabilitation for the following conditions:

  • Osteoarthritis and degenerative joint diseases

  • Muscle tension and myofascial pain syndromes

  • Tendinopathies (tendon disorders)

  • Bursitis and soft tissue inflammation

  • Back and neck pain

  • Sports injuries and overuse syndromes

  • Post-operative rehabilitation

  • Rheumatic conditions

  • Edema and localized inflammation

  • Chronic musculoskeletal pain syndromes

  • Support of tissue regeneration

Therapy Programs

The device includes an extensive program library for standardized applications:

Musculoskeletal System

  • Osteoarthritis / Arthritis

  • Muscle injuries and contractures

  • Tendinopathies

  • Fibromyalgia

  • Bursitis

  • Neuralgia and radiculopathy

  • Edema and hematoma

Body Regions

  • Shoulder (impingement, tendinitis, calcific shoulder)

  • Knee (meniscus injuries, ligament injuries, osteoarthritis)

  • Back and lumbar spine

  • Foot and ankle

  • Hand and elbow (e.g., epicondylitis, carpal tunnel syndrome)

  • Neck and cervical spine

Device Design and Operation

The PhysioLaser 12.0 Pro is a robust, portable system within the high-performance class.

  • 2.6” backlit display

  • Structured menu navigation

  • Fast program selection

  • Battery and mains operation

  • Carrying case for mobile use

  • Usable on treatment carts in clinical environments

The operation is designed for efficient use within medical laser therapy workflows.

Technical Data – Globus PhysioLaser 12.0 Pro

Feature Specification
Technology Medical laser therapy (GaAlAs diode, Class 4)
Wavelength 808 nm (optional 980 nm / 1064 nm depending on configuration)
Output Power up to 12 W ±20%
Emission continuous and pulsed
Frequency Range up to 10,000 Hz
Display 2.6” backlit
Power Supply battery and mains operation
Weight approx. 790 g
Dimensions 220 × 170 × 60 mm
Device Category Professional medical laser therapy device

Package Contents

  • PhysioLaser 12.0 Pro main unit (professional laser therapy device)

  • 808 nm laser handpiece with 11 mm and 22 mm optics (treatment applicator)

  • Protective glasses (for operator and patient)

  • Emergency stop button (safety shutdown)

  • Power supply unit

  • Carrying case (storage and transport)

  • User manual (application and safety information)

Globus PhysioLaser Model Comparison

Model Power Positioning Use Case Main Difference
PhysioLaser 2.0 up to 2 W entry level small practices compact standard therapy
PhysioLaser 6.0 up to 6 W standard physiotherapy & rehab higher power, broader use
PhysioLaser 6.0 Pro up to 6 W advanced high patient volume clinics more programs & flexibility
PhysioLaser 12.0 up to 12 W high performance large clinics significantly higher power
PhysioLaser 12.0 Pro up to 12 W maximum configuration specialized centers maximum features & system flexibility

More Information

Are you sure you would like to remove this item from the shopping cart?

This item is a part of the approved quote. Removing it will remove all quote items from the cart.