- High-performance device for medical laser therapy in physiotherapy and rehabilitation
- 12-watt laser treatment (808 nm) for high-intensity laser therapy
- Extended program library for standardized clinical applications
- Optionally expandable with additional wavelengths (depending on configuration)
- Designed for high patient throughput in professional practice and clinical environments
Availability: 5 - 7 working days
* incl. VAT excl. shipping
Convenient shipping
International convenient shipping throughout Europe
Secure shopping
Fast shipping, customer protection, secure payment
Description
Globus PhysioLaser 12.0 PRO – High-Performance Device
The GLOBUS PhysioLaser 12.0 PRO is a medical laser therapy device designed for professional use in physiotherapy, rehabilitation, orthopedics, and sports medicine. As a high-performance class system, it operates with a maximum output of 12 watts laser treatment (808 nm). The device is intended for regular use in clinics and physiotherapy practices and is particularly suitable for treating larger or more complex treatment areas. Its design allows flexible use in daily clinical workflows and supports structured, repeatable applications.
Key Features
-
Medical device for professional laser therapy applications
-
High-performance 12-watt laser treatment (808 nm) for intensive applications
-
Suitable for acute and chronic musculoskeletal conditions
-
Wide program library for standard physiotherapy indications
-
Optionally expandable to additional wavelengths (980 nm / 1064 nm depending on configuration)
-
Use in physiotherapy, orthopedics, and rehabilitation medicine
-
Treatment of larger body areas via high-performance optics
-
Battery and mains operation for flexible clinical use
-
Suitable for high patient volumes and regular treatments
-
Structured, program-guided operation
Laser Therapy Function
Laser therapy is based on the targeted application of light energy into biological tissue. The PhysioLaser 12.0 Pro operates at a standard wavelength of 808 nm, widely used in physical therapy for musculoskeletal treatment. The 12-watt output enables high energy delivery into tissue and is used for localized treatment of muscles, tendons, joints, as well as inflammatory and degenerative conditions. The application is non-invasive and delivered via a laser handpiece.
High-Intensity Laser Therapy in Clinical Practice
The PhysioLaser 12.0 Pro is designed for high-intensity laser therapy and enables efficient treatment of larger surface areas or deeper tissue structures due to its power reserve. The combination of high output and program-guided operation supports structured treatment workflows in both practice and clinical environments.
Indications
The PhysioLaser 12.0 Pro is used in physiotherapy and rehabilitation for the following conditions:
-
Osteoarthritis and degenerative joint diseases
-
Muscle tension and myofascial pain syndromes
-
Tendinopathies (tendon disorders)
-
Bursitis and soft tissue inflammation
-
Back and neck pain
-
Sports injuries and overuse syndromes
-
Post-operative rehabilitation
-
Rheumatic conditions
-
Edema and localized inflammation
-
Chronic musculoskeletal pain syndromes
-
Support of tissue regeneration
Therapy Programs
The device includes an extensive program library for standardized applications:
Musculoskeletal System
-
Osteoarthritis / Arthritis
-
Muscle injuries and contractures
-
Tendinopathies
-
Fibromyalgia
-
Bursitis
-
Neuralgia and radiculopathy
-
Edema and hematoma
Body Regions
-
Shoulder (impingement, tendinitis, calcific shoulder)
-
Knee (meniscus injuries, ligament injuries, osteoarthritis)
-
Back and lumbar spine
-
Foot and ankle
-
Hand and elbow (e.g., epicondylitis, carpal tunnel syndrome)
-
Neck and cervical spine
Device Design and Operation
The PhysioLaser 12.0 Pro is a robust, portable system within the high-performance class.
-
2.6” backlit display
-
Structured menu navigation
-
Fast program selection
-
Battery and mains operation
-
Carrying case for mobile use
-
Usable on treatment carts in clinical environments
The operation is designed for efficient use within medical laser therapy workflows.
Technical Data – Globus PhysioLaser 12.0 Pro
| Feature | Specification |
|---|---|
| Technology | Medical laser therapy (GaAlAs diode, Class 4) |
| Wavelength | 808 nm (optional 980 nm / 1064 nm depending on configuration) |
| Output Power | up to 12 W ±20% |
| Emission | continuous and pulsed |
| Frequency Range | up to 10,000 Hz |
| Display | 2.6” backlit |
| Power Supply | battery and mains operation |
| Weight | approx. 790 g |
| Dimensions | 220 × 170 × 60 mm |
| Device Category | Professional medical laser therapy device |
Package Contents
-
PhysioLaser 12.0 Pro main unit (professional laser therapy device)
-
808 nm laser handpiece with 11 mm and 22 mm optics (treatment applicator)
-
Protective glasses (for operator and patient)
-
Emergency stop button (safety shutdown)
-
Power supply unit
-
Carrying case (storage and transport)
-
User manual (application and safety information)
Globus PhysioLaser Model Comparison
| Model | Power | Positioning | Use Case | Main Difference |
|---|---|---|---|---|
| PhysioLaser 2.0 | up to 2 W | entry level | small practices | compact standard therapy |
| PhysioLaser 6.0 | up to 6 W | standard | physiotherapy & rehab | higher power, broader use |
| PhysioLaser 6.0 Pro | up to 6 W | advanced | high patient volume clinics | more programs & flexibility |
| PhysioLaser 12.0 | up to 12 W | high performance | large clinics | significantly higher power |
| PhysioLaser 12.0 Pro | up to 12 W | maximum configuration | specialized centers | maximum features & system flexibility |